浏览全部资源
扫码关注微信
目的 脉搏波传导时间法与袖带血压(示波法)测定值的对比研究。方法 入选2023年4月至9月在北京大学人民医院进行了直立倾斜试验的患者共92例(其中男49例,女43例),在直立倾斜试验中第1分钟和第15分钟进行血压测定,并同时采用脉搏波传导时间法进行血压连续测定。以袖带血压(示波法)测定值为参考血压,对血压连续测定值进行相关性、一致性分析和差值分析。结果 在各个时点下,两法测定的收缩压相关系数分别为0.897和0.832,舒张压相关系数分别为0.757和0.409,提示两法存在相关性。使用配对t检验进行δ差值分析发现,两个时点的收缩压δ差均值及第2个时点的舒张压δ差均值均小于1mm Hg,说明两法血压测定值比较接近,差值无统计学意义。Bland-Altman图结果显示,有95%数据在可信区间内,显示两种方法测定结果具有一定程度的一致性。对两法血压测定值的差值小于6mm Hg视为无差别,在第1个时点下,采用脉搏波传导时间法测定的收缩压值和舒张压值,分别是72%和78%。在第2个时间点下,分别是60%和72%。结论 脉搏波传导时间法与袖带血压(示波法)测定值具有良好的相关性及一致性。
智能可穿戴设备在中青年血压管理中应用中国专家共识[J]. 刘靖;刘静;张宇清;李燕.中华高血压杂志,2022(08)
2020中国动态血压监测指南[J]. Writing Group of the 2020 Chinese Hypertension League Guidelines on Ambulatory Blood Pressure Monitoring.中国循环杂志,2021(04)
Monitoring and analysis of cardiovascular pulse waveforms using flexible capacitive and piezoresistive pressure sensors and machine learning perspective.[J]. Chowdhury Azmal Huda;Jafarizadeh Borzooye;Baboukani Amin Rabiei;Pala Nezih;Wang Chunlei.Biosensors & bioelectronics,2023
Wearable Continuous Blood Pressure Monitoring Devices Based on Pulse Wave Transit Time and Pulse Arrival Time: A Review[J]. Zhou ZiBo;Cui TianRui;Li Ding;Jian JinMing;Li Zhen;Ji ShouRui;Li Xin;Xu JianDong;Liu HouFang;Yang Yi;Ren TianLing.Materials,2023
Validating cuffless continuous blood pressure monitoring devices[J]. Hu Jiun-Ruey;Martin Gabrielle;Iyengar Sanjna;Kovell Lara C.;Plante Timothy B.;Helmond Noud van;Dart Richard A.;Brady Tammy M.;Turkson-Ocran Ruth-Alma N.;Juraschek Stephen P..Cardiovascular Digital Health Journal,2023
Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability[J]. Stergiou George S.;Mukkamala Ramakrishna;Avolio Alberto;Kyriakoulis Konstantinos G.;Mieke Stephan;Murray Alan;Parati Gianfranco;Schutte Aletta E.;Sharman James E.;Asmar Roland;McManus Richard J.;Asayama Kei;De La Sierra Alejandro;Head Geoffrey;Kario Kazuomi;Kollias Anastasios;Myers Martin;Niiranen Teemu;Ohkubo Takayoshi;Wang Jiguang;Wuerzner Grégoire;O’Brien Eoin;Kreutz Reinhold;Palatini Paolo.Journal of Hypertension,2022
Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals[J]. Mukkamala Ramakrishna;Yavarimanesh Mohammad;Natarajan Keerthana;Hahn Jin Oh;Kyriakoulis G. Konstantinos;Avolio P. Alberto;Stergiou S. George.Hypertension,2021
Noninvasive Continuous Blood Pressure Estimation from Pulse Transit Time: A review of the calibration models.[J]. Barvik Daniel;Cerny Martin;Penhaker Marek;Noury Norbert.IEEE reviews in biomedical engineering,2021
Sources of Inaccuracy in Photoplethysmography for Continuous Cardiovascular Monitoring[J]. Fine Jesse;Branan Kimberly L.;Rodriguez Andres J.;Boonyaananta Tananant;Ajmal ;RamellaRoman Jessica C.;McShane Michael J.;Coté Gerard L..Biosensors,2021
2021 European Society of Hypertension practice guidelines for office and out-of-office blood pressure measurement[J]. Stergiou S. George;Palatini Paolo;Parati Gianfranco;O’Brien Eoin;Januszewicz Andrzej;Lurbe Empar;Persu Alexandre;Mancia Giuseppe;Kreutz Reinhold.Journal of Hypertension,2021
Design and Validation of a New PPG Module to Acquire High-Quality Physiological Signals for High-Accuracy Biomedical Sensing[J]. Kao Yung Hua;Chao Paul C. P.;Wey Chin Long.IEEE Journal of Selected Topics in Quantum Electronics,2019
Relation between blood pressure and pulse wave velocity for human arteries.[J]. Ma Yinji;Choi Jungil;Hourlier-Fargette Aurélie;Xue Yeguang;Chung Ha Uk;Lee Jong Yoon;Wang Xiufeng;Xie Zhaoqian;Kang Daeshik;Wang Heling;Han Seungyong;Kang Seung-Kyun;Kang Yisak;Yu Xinge;Slepian Marvin J;Raj Milan S;Model Jeffrey B;Feng Xue;Ghaffari Roozbeh;Rogers John A;Huang Yonggang.Proceedings of the National Academy of Sciences of the United States of America,2018
A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.[J]. Stergiou George S;Alpert Bruce;Mieke Stephan;Asmar Roland;Atkins Neil;Eckert Siegfried;Frick Gerhard;Friedman Bruce;Graßl Thomas;Ichikawa Tsutomu;Ioannidis John P;Lacy Peter;McManus Richard;Murray Alan;Myers Martin;Palatini Paolo;Parati Gianfranco;Quinn David;Sarkis Josh;Shennan Andrew;Usuda Takashi;Wang Jiguang;Wu Colin O;O'Brien Eoin.Hypertension (Dallas, Tex. : 1979),2018
Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.[J]. Ding Xiaorong;Yan Bryan P;Zhang Yuan-Ting;Liu Jing;Zhao Ni;Tsang Hon Ki.Scientific reports,2017
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring.[J]. Kachuee Mohammad;Kiani Mohammad Mahdi;Mohammadzade Hoda;Shabany Mahdi.IEEE transactions on bio-medical engineering,2017
Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.[J]. Bilo Grzegorz;Zorzi Cristina;Ochoa Munera Juan E;Torlasco Camilla;Giuli Valentina;Parati Gianfranco.Blood pressure monitoring,2015
Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement.[J]. Patzak Andreas;Mendoza Yuri;Gesche Heiko;Konermann Martin.Blood pressure,2015
A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time[J]. Dilpreet Buxi;Jean-Michel Redouté;Mehmet Rasit Yuce.Physiological Measurement,2015
Pulse transit time as a surrogate measure of changes in systolic arterial pressure in children during sleep.[J]. Vlahandonis Anna;Biggs Sarah N;Nixon Gillian M;Davey Margot J;Walter Lisa M;Horne Rosemary S C.Journal of sleep research,2014
Blood pressure and incidence of twelve cardiovascular diseases: lifetime risks, healthy life-years lost, and age-specific associations in 1·25 million people[J]. Eleni Rapsomaniki;Adam Timmis;Julie George;Mar Pujades-Rodriguez;Anoop D Shah;Spiros Denaxas;Ian R White;Mark J Caulfield;John E Deanfield;Liam Smeeth;Bryan Williams;Aroon Hingorani;Harry Hemingway.The Lancet,2014
Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis.[J]. Kim Sang-Hyun;Lilot Marc;Sidhu Kulraj S;Rinehart Joseph;Yu Zhaoxia;Canales Cecilia;Cannesson Maxime.Anesthesiology,2014
Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome[J]. Agnes S. Meidert;Wolfgang Huber;Alexander Hapfelmeier;Miriam Schöfthaler;Johannes N. Müller;Nicolas Langwieser;Julia Y. Wagner;Roland M. Schmid;Bernd Saugel.Journal of Critical Care,2013
Comparison of bilateral pulse arrival time before and after induced vasodilation by axillary block[J]. Minke C Kortekaas;Sjoerd P Niehof;Marit H N van Velzen;Eilish M Galvin;Robert J Stolker;Frank J P M Huygen.Physiological Measurement,2012
Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method.[J]. Gesche Heiko;Grosskurth Detlef;Küchler Gert;Patzak Andreas.European journal of applied physiology,2012
Continuous non-invasive arterial pressure measurement: Evaluation of CNAP⢠device during vascular surgery[J]. M. Biais;L. Vidil;S. Roullet;F. Masson;A. Quinart;P. Revel;F. Sztark.Annales Françaises d'Anesthésie et de Réanimation,2010
Noninvasive Measurement of Central Vascular Pressures With Arterial Tonometry: Clinical Revival of the Pulse Pressure Waveform?[J]. Nelson, Matthew R;Stepanek, Jan;Cevette, Michael;Covalciuc, Michael;Hurst, R Todd;Tajik, A Jamil.Mayo Clinic Proceedings,2010
Prognostic significance of blood pressure and heart rate variabilities: the Ohasama study.[J]. Kikuya M;Hozawa A;Ohokubo T;Tsuji I;Michimata M;Matsubara M;Ota M;Nagai K;Araki T;Satoh H;Ito S;Hisamichi S;Imai Y.Hypertension (Dallas, Tex. : 1979),2000
Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia.[J]. Kemmotsu O;Ueda M;Otsuka H;Yamamura T;Winter D C;Eckerle J S.Anesthesiology,1991(2)
0
Views
33
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621