黄艳, 吕娜, 朱璐, 等. 远程可穿戴心电设备的应用进展[J]. 临床心电学杂志, 2022,(2):143-148.
Application progress of remote wearable electrocardiography devices[J]. 2022, (2): 143-148.
心电图实时记录心脏的电活动,为检测各种心血管疾病提供了重要的机会。目前,12导联心电图作为标准心电图采集技术用于诊断心律失常以外的许多心脏疾病。然而,12导联心电图的使用仅限于训练有素的医务人员,限制了其使用范围。远程可穿戴心电设备已经试图弥补这一缺陷,让患者能够使用简化的方法,即减少导联的数量(通常是单导联)来获取自身的心电图。其与实时通知技术相结合,可用于心律失常的检测,有充分的证据表明,在诊断特殊心律失常时(如心房颤动),远程心电设备比传统12导联心电图更可靠,在长程监测方面具有巨大潜力。本文对远程心电设备及其在心律失常诊断中的临床应用、面临的重要挑战和局限性进行综述。
Electrocardiogram(ECG)
which records the electrical activity of the heart in real time
provides an important opportunity to detect various cardiovascular diseases. Currently
12-lead ECG is used as a standard ECG acquisition technique to diagnose many cardiac diseases other than arrhythmia. However
the use of 12-lead ECG is limited to trained medical personnel
limiting its use. Remote wearable ECG devices have attempted to remedy this by allowing patients to obtain their own ECG using a simplified method of reducing the number of leads(usually single leads). Combined with real-time notification technology
it can be used for the detection of arrhythmia
and there is good evidence that Remote ECG devices are more reliable than traditional 12-lead ECG for the diagnosis of specific arrhythmia
such as atrial fibrillation
and have great potential for long-range monitoring. This article reviews the clinical application
challenges and limitations of remote ECG devices in the diagnosis of arrhythmia.
Comparison of electrocardiograms (ECG) waveforms and centralized ECG measurements between a simple 6-lead mobile ECG device and a standard 12-lead ECG.[J]. Kleiman Robert;Darpo Borje;Brown Randy;Rudo Todd;Chamoun Svetlana;Albert David E;Bos Johan Martijn;Ackerman Michael J.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc,2021
Smartphone electrocardiogram for detecting atrial fibrillation after a cerebral ischaemic event: a multicentre randomized controlled trial[J]. Koh Keng Tat;Law Wan Chung;Zaw Win Moe;Foo Diana Hui Ping;Tan Chen Ting;Steven Anderson;Samuel Desmond;Fam Tem Lom;Chai Ching Hua;Wong Zhai Sing;Xaviar Sivaraj;Bhavnani Chandan Deepak;Tan Jason Seng Hong;Oon Yen Yee;Said Asri;Fong Alan Yean Yip;Ong Tiong Kiam.EP Europace,2021(7)
QT Interval Monitoring with Handheld Heart Rhythm ECG Device in COVID-19 Patients.[J]. MinguitoCarazo Carlos;EcharteMorales Julio;BenitoGonzález Tomás;Del CastilloGarcía Samuel;RodríguezSantamarta Miguel;SánchezMu?oz Enrique;Maniega Clea González;GarcíaBergel Rubén;MenéndezSuárez Paula;PrietoGonzález Silvia;PalaciosEchavarren Carmen;BorregoRodríguez Javier;FloresVergara Guisela;IglesiasGarriz Ignacio;FernándezVázquez Felipe.Global heart,2021(1)
Measurement of the QT interval using the Apple Watch.[J]. Spaccarotella Carmen Anna Maria;Migliarino Serena;Mongiardo Annalisa;Sabatino Jolanda;Santarpia Giuseppe;De Rosa Salvatore;Curcio Antonio;Indolfi Ciro.Scientific reports,2021(1)
Performance of a Mobile Single-Lead Electrocardiogram Technology for Atrial Fibrillation Screening in a Semirural African Population: Insights From "The Heart of Ethiopia: Focus on Atrial Fibrillation" (TEFF-AF) Study.[J]. Pitman Bradley M;Chew SokHui;Wong Christopher X;Jaghoori Amenah;Iwai Shinsuke;Thomas Gijo;Chew Andrew;Sanders Prashanthan;Lau Dennis H.JMIR mHealth and uHealth,2021(5)
Feasibility and Reliability of SmartWatch to Obtain 3-Lead Electrocardiogram Recordings[J]. Behzadi Amirali;Sepehri Shamloo Alireza;Mouratis Konstantinos;Hindricks Gerhard;Arya Arash;Bollmann Andreas.Sensors,2020(18)
Evaluation of general practitioners' single-lead electrocardiogram interpretation skills: a case-vignette study.[J]. Karregat Evert P M;Himmelreich Jelle C L;Lucassen Wim A M;Busschers Wim B;van Weert Henk C P M;Harskamp Ralf E.Family practice,2020(2)
Standard and Precordial Leads Obtained With an Apple Watch.[J]. Macfarlane Peter W.Annals of internal medicine,2020(3)
Diagnosing atrial fibrillation by mobile technology: physician decision or device provision?[J]. Frisch Daniel R.Heart (British Cardiac Society),2020(9)
Comprehensive Evaluation of Rhythm Monitoring Strategies in Screening for Atrial Fibrillation: Insights From Patients at Risk Monitored Long Term With an Implantable Loop Recorder.[J]. Diederichsen S?ren Z?ga;Haugan Ketil J?rgen;Kronborg Christian;Graff Claus;H?jberg S?ren;K?ber Lars;Krieger Derk;Holst Anders Gaarsdal;Nielsen Jonas Bille;Brandes Axel;Svendsen Jesper Hastrup.Circulation,2020(19)
Smart watch recording of ventricular tachycardia: Case study[J]. Maxime Ringwald;Alexandre Crich;Nicolas Beysard.American Journal of Emergency Medicine,2020(4)
Accuracy of Apple Watch for Detection of Atrial Fibrillation.[J]. Seshadri Dhruv R;Bittel Barbara;Browsky Dalton;Houghtaling Penny;Drummond Colin K;Desai Milind Y;Gillinov A Marc.Circulation,2020(8)
Smartphone ECG Monitoring System Helps Lower Emergency Room and Clinic Visits in Post-Atrial Fibrillation Ablation Patients.[J]. Aljuaid Mossab;Marashly Qussay;AlDanaf Jad;Tawhari Ibrahim;Barakat Michel;Barakat Rody;Zobell Brittany;Cho William;Chelu Mihail G;Marrouche Nassir F.Clinical Medicine Insights. Cardiology,2020
Recurrent atrial fibrillation/flutter detection after ablation or cardioversion using the AliveCor KardiaMobile device: iHEART results.[J]. Goldenthal Isaac L;Sciacca Robert R;Riga Teresa;Bakken Suzanne;Baumeister Maurita;Biviano Angelo B;Dizon Jose M;Wang Daniel;Wang Ketty C;Whang William;Hickey Kathleen T;Garan Hasan.Journal of cardiovascular electrophysiology,2019(11)
Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care.[J]. Himmelreich Jelle C L;Karregat Evert P M;Lucassen Wim A M;van Weert Henk C P M;de Groot Joris R;Handoko M Louis;Nijveldt Robin;Harskamp Ralf E.Annals of family medicine,2019(5)
Recording of Bipolar Multichannel ECGs by a Smartwatch: Modern ECG Diagnostic 100 Years after Einthoven[J]. Alexander Samol;Kristina Bischof;Blerim Luani;Dan Pascut;Marcus Wiemer;Sven Kaese.Sensors,2019(13)
Novel Use of Apple Watch 4 to Obtain 3-Lead Electrocardiogram and Detect Cardiac Ischemia.[J]. Avila Cesar O.The Permanente journal,2019
Improved accuracy and confidence with multiple-lead recordings from a single-lead mobile electrocardiographic device.[J]. Frisch Daniel R;Weiss Max;Dikdan Sean J;Keith Scott W;Sarkar Kumar.Pacing and clinical electrophysiology : PACE,2019(9)
Atrial fibrillation detection using single lead portable electrocardiographic monitoring: a systematic review and meta-analysis.[J]. Ramkumar Satish;Nerlekar Nitesh;D'Souza Daniel;Pol Derek J;Kalman Jonathan M;Marwick Thomas H.BMJ open,2018(9)
Wearable Devices in Clinical Trials: Hype and Hypothesis.[J]. Izmailova Elena S;Wagner John A;Perakslis Eric D.Clinical pharmacology and therapeutics,2018(1)
Comparison of two ambulatory patch ECG monitors: The benefit of the P- wave and signal clarity[J]. Robert Rho;Mark Vossler;Susan Blancher ARNP;Jeanne E. Poole.American Heart Journal,2018
Diagnostic yield of asymptomatic arrhythmias detected by mobile cardiac outpatient telemetry and autotrigger looping event cardiac monitors.[J]. Derkac Wayne M;Finkelmeier Jeffrey R;Horgan Daniel J;Hutchinson Mathew D.Journal of cardiovascular electrophysiology,2017(12)
Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours[J]. Warren M. Smith;Fiona Riddell;Morag Madon;Marye J. Gleva.American Heart Journal,2017
Wireless Technology in Disease Management and Medicine[J]. Gari D. Clifford;David Clifton.Annual Review of Medicine,2012
Fundamentals of electrocardiography interpretation.[J]. Becker Daniel E.Anesthesia progress,2006(2)
Comparison of Autotriggered Memory Loop Recorders Versus Standard Loop Recorders Versus 24-Hour Holter Monitors for Arrhythmia Detection[J]. James A. Reiffel;Robert Schwarzberg;Maria Murry.The American Journal of Cardiology,2005(9)
Computational studies of transthoracic and transvenous defibrillation in a detailed 3-D human thorax model.[J]. Jorgenson D B;Haynor D R;Bardy G H;Kim Y.IEEE transactions on bio-medical engineering,1995(2)
Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions[J]. Pahlm Olle;Haisty Wesley K.;Edenbrandt Lars;Wagner Nancy B.;Sevilla Dorina C.;Selvester Ronald H.;Wagner Galen S..The American Journal of Cardiology,1992(3)
Variability of electrocardiographic precordial lead placement: a method to improve accuracy and reliability.[J]. Herman M V;Ingram D A;Levy J A;Cook J R;Athans R J.Clinical cardiology,1991(6)
Clinically significant differences between the "old" analog and the "new" digital electrocardiograms.[J]. Garson A.American heart journal,1987(1 Pt)
0
浏览量
240
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621